 tfs 150F4.doc
Version 3.0
06.01.02
VI TELEFILTER
1. Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc: 23 C 0 dBm. for input: for output:
Filter Specification
TFS 150F - 1/3
313 - 11,74 pF. 2620 - 4,2 pF.
2. Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 150F2 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequence fc is the arithmetic mean value of the upper and lower frequencies at the 32 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range.
Data Insertion loss (Reference level) Centre frequency ae
typ. value 29 150 dB MHz
tolerance / limit max. 35 150,00,05 fC-4,80 MHz.....fC+4,80 dB MHz MHz dB
fc at ambient temperature TA (fCAT)
Pass band at ambient temperature TA: Amplitude ripple in pass band (p-p): fC ... fC 4,80 MHz Bandwidth at ambient temperature: 0,8 dB - band width 1,0 dB - band width 2 dB - band width 3 dB - band width 25 dB - band width 32 dB - band width Relative attenuation 9,93 10,010 10,066 10,137 10,653 10,730 arel MHz MHz MHz MHz MHz MHz 0,5 dB
max. 0,8
min. 9,6 min. 10,0
MHz MHz
max. 10,8
MHz
fC fC 4,80 MHz max. 0,8 dB MHz ..... fC 4,975 MHz max. 2 dB fC 4,80 MHz max. 3 dB fC 4,975 MHz ..... fC 5,0 MHz ..... fC 8,75 MHz 34....50 dB min. 32...45 dB fC 5,4 In the frequency range fc 5,4 MHz ... fc 8,75 MHz the type of the LIMIT LINE is a SLOPING LINE (SL). MHz ..... fC 48,75 MHz 55...70 dB min 45 dB fC 8,75 65...70 dB fC 48,75 MHz ..... fC 98,75 MHz Group delay ( mean value in pass band ): 2,875 s max 5 s Group delay ripple in pass band (p-p): 50...70 ns max 120 ns Deviation from linear phase in pass band (p-p): 2,6 (r.m.s. 0,5) Triple transit attenuation compared to main signal 66 dB Crosstalk 52...56 dB Frequency inversion temperature ( To ) 10 C -0,054 ppm/K Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature: * ) fc(Hz) = Tcf(ppm/K) x (T - To) x fTo (MHz) Operating temperature range - 25 C ... + 75 C Storage temperature range - 40 C ... + 85 C Input power level max. + 10 dBm.
* ) fTo is reference frequence fc at frequency inversion temperature (To )
Generated:
Dunzow W.P.
Checked/Approved:
Dr. Bert Wall
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs 150F4.doc
Version 3.0
06.01.02
VI TELEFILTER 3. Package
Filter Specification
TFS 150F - 2/3
TFS 150F TFS71 E tft L10 tft L8
Pin 1 Pin 14 Pin 8 Pin 7 Pin 2,9
Input Input RF Return Output Output RF Return Pakage Ground
4. 50 matching network:
12
7
C1
L1
14 9 8
L2
C2
Remark: L1 , L2 have to be adjusted (refer to Application Note TFS 150F).
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs 150F4.doc
Version 3.0
06.01.02
VI TELEFILTER
Filter Specification
TFS 150F - 3/3
5. Air reflow temperature conditions
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS150F

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X